Elemental and Isotopic Analysis


High-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS)

ELEMENT XR (Thermo Fisher Scientific)

ELEMENT XR (Thermo Fisher Scientific)

Description

The Element XR is a double-focusing inductively coupled plasma mass spectrometer (reverse Nier-Johnson geometry) offering variable mass resolution (R = 300, 4000 and 10,000). It features a triple detection system combining a discrete-dynode secondary electron multiplier (SEM), operating in pulse-counting and analog modes, with a Faraday cup for the detection of high-intensity signals.

This configuration enables the elimination of the most common spectral interferences and provides a wide dynamic measurement range spanning twelve orders of magnitude, suitable for both the analysis of elements present at high concentrations (> 1000 mg/L) and the determination of ultra-trace concentrations (< pg/L).

Installed in an ISO 7 clean room, the Element XR is coupled, for solution analysis, to an integrated SC-E2 autosampler equipped with a FAST injection loop or to an APEX-Q/APEX Ω membrane desolvation system. The instrument enables elemental and isotopic determination in a wide variety of sample matrices of interest.

Applications

  • Natural analogues of radionuclides and chemical toxicants (CT) at ultra-trace levels, as well as elements from radioactive waste storage matrices (clay, cement, glass and steel). The data contribute to understanding radionuclide transfer through natural and engineered storage barriers as well as the alteration of these barriers.
  • Natural radionuclide ²²⁶Ra, with a detection limit (DL) of 0.02 pg L⁻¹ (0.8 mBq L⁻¹), in radiologically impacted environmental samples (natural mineral spring waters and DGT/DET passive samplers deployed in water and sediments from former uranium mining sites) to investigate the impact, behavior and transport of naturally occurring radionuclides in the environment.

Triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS-TQ)

iCAP-TQ (Thermo Fisher Scientific)

iCAP-TQ (Thermo Fisher Scientific)

Description

The iCAP TQ features a triple-quadrupole configuration combining two mass filters with a collision/reaction cell (Q Cell), which removes spectral interferences using a collision gas (He) and reaction gases (O₂ and NH₃). The Rapid Lens ion optics, oriented at 90°, optimize ion transmission across the entire mass range while reducing instrumental background.

Elements are detected using a secondary electron multiplier (SEM) with a linear response spanning more than ten orders of magnitude, either in “on-mass” mode without a mass shift or in “mass-shift” mode at the mass of the product formed in the cell.

This design provides high sensitivity, optimized abundance sensitivity (0.005 ppm), and low detection limits for multi-element and isotopic analysis of samples with a wide range of matrices.

The iCAP-TQ operates with an SC-4 DX autosampler equipped with a FAST injection loop, a gas dilution kit for the analysis of highly concentrated solutions (dissolved salt contents > 30%), and an APEX-Q/APEX Ω membrane desolvation system.

Applications

  • Natural analogues of radionuclides and chemical toxicants, as well as major elements from nuclear materials (clay, cement, glass, steel, geopolymer and zirconium alloy), for applications related to radioactive waste treatment, conditioning and storage.
  • Multi-element profiles and naturally occurring radionuclides (²³⁸U) measured using DET/DGT techniques in radiologically impacted soil cores.